1650CC PID Carbon controller dual loop, 1/8 DIN

Home / Controllers and Indicators / Controllers and programmers

  • Description

Overview

PID controller and measurement of carbon potential in metal heat treatment applications.
The direct connection of the zirconium oxide probes, the efficient algorithm for percentage of carbon calculation inside the furnace combined with a precise PID control, provides a safe and compact control solution even for critical applications.

Single / Dual loop PID controller
Thanks to the third analog input, in addition to the temperature and mV signals required for zirconia probe management, the 1650CC controller is able to control both the Carbon Potential control loop and the furnace temperature control loop.  

Embedded Zirconia proble cleaning Burnoff sequence
The zirconium oxygen probe is a particularly sensitive sensor and due to its installation inside a furnace with a carbon-rich atmosphere, after several hours of operation, it needs cyclic cleaning sequences to remove material deposition on the measuring element, a problem that can cause an error in the measurement of the carbon percentage or reduce the average life of the probe.
For this purpose, the PID controller automatically manages the timed cleaning sequence, also handling the status of the calculated values, which must remain frozen during the cleaning phase.

Zirconia probe diagnostics
Probe diagnostics, useful to verify and ensure the correct functionality of the measurement sensor. Two typical values are used to evaluate proper probe functionality, the impedance and the mV voltage recovery ramp after a Burnoff purge sequence.
Deviation of these values over time, indicating a probe problem, are monitored and reported as alarms by the new Carbon Controller series.  Likewise, any errors during the cyclic purge phase are reported.  

Connectivity and Remote Service
Modbus RTU master/slave, Modbus TCP slave and Modbus RTU/TCP bridge.
Embedded Webserver interface for fast and easy remote assistance.

Related products

Quick View

Controllers and Indicators

1350 Controller PID, 1/4 DIN

Quick View

Controllers and Indicators

650L Indicator/Safety Alarm Limit (FM)

Quick View

Controllers and Indicators

40T96 Indicator/Alarm Unit

Quick View

Controllers and Indicators

1850 PID Controller double loop, 1/4 DIN

Quick View

Controllers and Indicators

1600 Controller PID, 1/8 DIN

Quick View

Controllers and Indicators

GFXTermo4 PID Controller 4 loops for DIN rail

Quick View

Controllers and Indicators

1650 Double loop PID Controller, 1/8 DIN

Quick View

Controllers and Indicators

800P PID Controller Programmer, 1/16 DIN

About Us
  • Company
  • Resources
  • Blog
Quick links
  • Home
  • About Us
Questions
  • FAQ
  • Contact Us
Follow Us
  • Privacy Policy
  • Terms and Conditions
  • Cookies Policy

Copyright © 2020, Ermen Systems Ltd, Ground Floor Block D, Monksland Business Park, Monksland, Athlone, Co. Roscommon, N37 X3H9

  • Industrial Automation
    • Gefran
  • Light Sanitation
    • Biovitae LED Lighting
  • Ventilation
    • Domestic Fans
    • De-Centralised MVHR
    • De-Centralised MVHR with Air Sanitization
    • Mechanical Ventilation with De-Humidification
    • ASPIRCOMFORT PRO X 460H VENTILATION WITH HEATING COOLING
    • Aspircomfort PRO X 380V Ventilation With Heating Cooling
    • ECO 2.0 Smart Ventilation
  • Destratification
    • Airius Destratification
    • Pureair

Login

Lost your password?

×

REQUEST A FREE ESTIMATE