SONTAY GENERAL

Sontay
blank

Collecting and analysing data is key component in assisting the people to analyse Indoor Air Quality and to meet its energy target

The key parameters to be measured and analysed are:

  • Temperature
  • Relative Humidity
  • CO2
  • VOC’s: Volatile Organic Compounds
  • Air Quality

What is a heat cost allocator?

What is a Smart building?

A Smart Building refers to “the ability of a building or its systems to sense, interpret, communicate and actively respond in an efficient manner to changing conditions in relation to the operation of technical building system or the external environment and to demands from building occupants.”

Sontay Smart Sensors

The new Smart Sensor from Sontay enables people/businesses to collect and correlate all the data required, to address IAQ issues and reduce Energy/Operating costs.

A Smart building would be nothing without the variety of sensors that monitor and analyse environmental conditions on a day to day basis, then provide the information to the building control system. Sensors are constantly working, providing valuable data back to the control system.

3 CORE PILLARS:

  • Improve Energy Efficiency
  • Maintain Healthy Indoor Climate
  • Manage Electricity Demand.

Sontay SMART Sensor:

Sontay’s new generation of Smart sensor can offer full environmental sensing in one single device. This sensor can measure;

  • Temperature
  • Relative Humidity
  • CO2 Carbon Dioxide
  • CO Carbon Monoxide
  • Air Quality
  • Light Level
  • Occupancy

The sensor also offers user interface options, e.g. Set Point, Fan Speed and Momentary Switches.

The result is a faster, more efficient installation where controller and I/O requirements are reduced.

Network Smart Sensors

Benefits:

  • Greater comfort and control for the End User
  • Ease of data monitoring assist the Building Manager
  • Simplified & low cost for the Systems Integrator

There are also Sensors available to monitor individual parameters if necessary:

blank

Air Quality

blank

CO2

blank

RH +T

SONTAY Portfolio:

Air Quality & Gas Detection

blank

blank

GL Gas Leak Alarm System

Gas Leak Alarm Systems A range of gas leak detection systems for natural gas, LPG and Carbon Monoxide.

blank

GS Air Quality, Carbon Dioxide/RH & T & Gas Sensors

Carbon Dioxide/RH & T & Gas Sensors, a range of sensors for indoor air quality (VOC), CO2, CO and common exhaust gases.

blank

SD Duct Smoke Detector

Duct Smoke Detector Duct mounting smoke detector for monitoring and alarm applications.

Air & Water Flow

blank

blank

AV Air Velocity Sensor & Probe

Air Velocity Sensors & Probes A range of single and multipoint air velocity probes and sensors, plus wind speed and direction sensors for outdoor use.

blank

FS Air & Liquid Flow Switches

Air & Liquid Flow Switches A range of paddle switches for air and liquid flow proving in ducts and pipes.

blank

LS Liquid Level Switches & Sensors

Liquid Level Switches & Sensors A range of float switches, and capacitive or ultrasonic level sensors for liquids.

Controllers

blank

blank

FC Fan Speed Controllers

Fan Speed Controllers A range of manual or automatic motor speed controllers, ideal for single-phase fans.

blank

RE Electric Heater Battery Controllers

Electric Heater Battery Controllers A range of single and 3-phase controllers for electric heater batteries and resistive loads, from 1.5kW to 86kW.

Input/Output Modules

blank

blank

IO Input/Output Modules

IO Input / Output Modules IO modules offer capability for rescaling, converting, isolating and overriding signals from BMS controllers

Light Level & Occupancy

blank

blank

LL Light Level Controllers & Sensors

Light Level Controllers & Sensors A range of ceiling mount lighting controllers, and wall and outside light level sensors.

blank

OC Occupancy detectors

A range of wall and ceiling mounted occupancy detectors to monitor and control spaces in building.

Pressure

blank

blank

PA Air DP Sensors & Switches

Air DP Sensors & Switches Air DP switches for fan proving, single or multi-range air DP sensors for dirty filter monitoring and air flow or pressure control.

blank

PL Liquid Pressure Sensors & Switches

Monitor flow and prove pumps, chillers and valves. These sensors can be used to measure static pressure in a large range of liquids and gases.

Relative Humidity & Temperature

blank

RH-CAL

We can now offer in-house calibration of our temperature and relative humidity sensors. Our state of the art calibration chamber is tested to UKAS standards and we can provide test certificates for 3-point calibration with additional points if required.

blank

PL Liquid Pressure Sensors & Switches

A valuable feature of this sensor is when in 3-wire mode it automatically detects what the controller input is set to, 4-20mA or 0-10Vdc. This removes the requirement for output jumpers that can be inadvertently set incorrectly. 2-wire loop powering selectable via DIP switch. It also provides on board LED indication for power status and fault find.

blank

RH-D-UN – Single Output Duct Relative Humidity Sensor

A valuable feature of this sensor is its ability to automatically detect what the controller input its set to, 4-20mA or 0-10Vdc. This removes the requirement for output jumpers that can be inadvertently set incorrectly. On board LED indication of which output type is in operation is provided. Also available with a passive resistive output for temperature, along with other passive outputs.

blank

RH-O – Outside Mount RH & T Sensor

A valuable feature of this sensor is when in 3-wire mode it automatically detects what the controller input is set to, 4-20mA or 0-10Vdc. This removes the requirement for output jumpers that can be inadvertently set incorrectly. 2-wire loop powering selectable via DIP switch. It also provides on board LED indication for power status and fault find.

blank

RH-O-UN – Single Output Outside Relative Humidity Sensor

A valuable feature of this sensor is its ability to automatically detect what the controller input its set to, 4-20mA or 0-10Vdc. This removes the requirement for output jumpers that can be inadvertently set incorrectly. On board LED indication of which output type is in operation is provided. Also available with a passive resistive output for temperature, along with other passive outputs.

blank

RH-R – Remote probe RH & T Transmitter (±3%)

A valuable feature of this sensor is when in 3-wire mode it automatically detects what the controller input is set to, 4-20mA or 0-10Vdc. This removes the requirement for output jumpers that can be inadvertently set incorrectly. 2-wire loop powering selectable via DIP switch. It also provides on board LED indication for power status and fault find.

blank

RH-S – Space Relative Humidity and Temperature Sensor

A valuable feature of this sensor is when in 3-wire mode it automatically detects what the controller input is set to, 4-20mA or 0-10Vdc. This removes the requirement for output jumpers that can be inadvertently set incorrectly. 2-wire loop powering selectable via DIP switch. It also provides on board LED indication for power status and fault find.

blank

RH-SH Humidistats

RH-SH humidistats are designed for the on/off control of humidification and dehumidification equipment, or the initiation of alarms or override controls. High quality sensing elements ensure accurate measurement and switching differential.

blank

RH-S-UN – Single Output Space Relative Humidity Sensor

A valuable feature of this sensor is its ability to automatically detect what the controller input its set to, 4-20mA or 0-10Vdc. This removes the requirement for output jumpers that can be inadvertently set incorrectly. On board LED indication of which output type is in operation is provided. Also available with a passive resistive output for temperature, along with other passive outputs.

blank

RH-W – Wall Mount RH& T Sensor

A valuable feature of this sensor is when in 3-wire mode it automatically detects what the controller input is set to, 4-20mA or 0-10Vdc. This removes the requirement for output jumpers that can be inadvertently set incorrectly. 2-wire loop powering selectable via DIP switch. It also provides on board LED indication for power status and fault find.

blank

RH-W-UN – Single Output Wall Relative Humidity Sensor

A valuable feature of this sensor is its ability to automatically detect what the controller input its set to, 4-20mA or 0-10Vdc. This removes the requirement for output jumpers that can be inadvertently set incorrectly. On board LED indication of which output type is in operation is provided.Also available with a passive resistive output for temperature, along with other passive outputs.

Temperature

blank

blank

ST Temperature Thermostats

A series of capillary, duct, immersion, frost, strap-on and space thermostats, with auto or manual reset and a variety of temperature ranges to suit every application.

blank

TT S Space Sensors

Our temperature and sensors are renowned for their accuracy and reliability and are available for a variety of applications.

blank

TT Temperature Sensors

Our temperature sensors are renowned for their accuracy and reliability and are available for a variety of applications.

blank

UI User Interfaces & Alarm Annunciators

User Interfaces & Alarm Annunciators interfaces on a range of single/double-gang plates in a range of materials, plus single or dual channel alarm annunciators.

Water Detection & Emergency Products

blank

blank

EP Emergency Stop

Emergency stop solutions for emergency gas shut-off of gas solenoid valves.

blank

WD Water Detection System

Sontay’s Water Leak Detection System is designed to detect leaks either at localised points sensor or larger areas, a rain sensor is also available.

blank

WD-CPS Condensation Detection and Prevention

Condensation prevention sensor and switch as well as detection plate.

Wireless

blank

blank

RF-A SonNet Accesories

Accessories that allow you to develop the award-winning system further.

blank

RF-IOM SonNet Input/Output Modules

This intelligent device is used in conjunction with SonNet sensors & routers to act as local I/O with connectivity to typical HVAC equipment such as fan coil units.

blank

RF-RR SonNet Routers

These routers are used in conjunction with the Sontay RF-RX20, RF-RX40 or RF-RXS receiver units.

blank

RF-RS SonNet Sensors

Sensor nodes are used in conjunction with the Sontay RF-RX20, RF-RX40 or RF-RXS receiver units.

blank

RF-RX SonNet Recievers

The Sontay receivers collects data from all other devices on the radio network,